Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.514
Filtrar
1.
Environ Toxicol Chem ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38661510

RESUMO

Pharmaceuticals are found in aquatic environments due to their widespread use and environmental persistence. To date, a range of impairments to aquatic organisms has been reported with exposure to pharmaceuticals; however, further comparisons of their impacts across different species on the molecular level are needed. In the present study, the crustacean Daphnia magna and the freshwater fish Japanese medaka, common model organisms in aquatic toxicity, were exposed for 48 h to the common analgesics acetaminophen (ACT), diclofenac (DCF), and ibuprofen (IBU) at sublethal concentrations. A targeted metabolomic-based approach, using liquid chromatography-tandem mass spectrometry to quantify polar metabolites from individual daphnids and fish was used. Multivariate analyses and metabolite changes identified differences in the metabolite profile for D. magna and medaka, with more metabolic perturbations for D. magna. Pathway analyses uncovered disruptions to pathways associated with protein synthesis and amino acid metabolism with D. magna exposure to all three analgesics. In contrast, medaka exposure resulted in disrupted pathways with DCF only and not ACT and IBU. Overall, the observed perturbations in the biochemistry of both organisms were different and consistent with assessments using other endpoints reporting that D. magna is more sensitive to pollutants than medaka in short-term studies. Our findings demonstrate that molecular-level responses to analgesic exposure can reflect observations of other endpoints, such as immobilization and mortality. Thus, environmental metabolomics can be a valuable tool for selecting sentinel species for the biomonitoring of freshwater ecosystems while also uncovering mechanistic information. Environ Toxicol Chem 2024;00:1-13. © 2024 The Authors. Environmental Toxicology and Chemistry published by Wiley Periodicals LLC on behalf of SETAC.

2.
J Chromatogr A ; 1724: 464928, 2024 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-38663320

RESUMO

Colorants have been a staple in the cosmetics industry for a considerable time, although certain varieties have been banned owing to health risks. Detecting and confirming these banned colorants simultaneously poses several challenges when employing LC-MS/MS. Molecular networking is a promising analytical technology that can be used to predict the structure of components and the correlation between them using structural and MS/MS spectral similarities. Molecular networking entails assessing the number of fragmented ions and the cosine score (the closer it is to one, the higher the similarity). In this study, we developed and verified a method for the simultaneous quantitative analysis of the 26 banned colorants in cosmetics using LC-MS/MS. Additionally, we propose a novel approach that combines LC-Q-TOF-MS and molecular networking technology to detect banned colorants in cosmetics. For successful molecular networking, a minimum of six fragment ions with cosine scores exceeding 0.5 is required. We developed a screening method for characterizing banned colorants using molecular networking based on LC-TOF-MS results for 26 banned colorants. Furthermore, we demonstrated that our established method can be used for screening by analyzing actual cosmetics (eyebrow tattoo, lipstick tattoo, and hair tint) spiked with three non-targeted banned colorants with similar structures (m/z 267.116, 315.149, and 345.157) in cosmetics. The combination of molecular networking techniques and LC-MS/MS proves highly advantageous for the swift characterization and screening of non-targeted colorants in cosmetics.

3.
Drug Test Anal ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38663892

RESUMO

Phosphatidylethanol (PEth) measurement in whole blood samples is established as a specific alcohol biomarker with clinical and forensic applications. Establishment of dried blood spots (DBSs) as a specimen for PEth determination offers several advantages and was the focus of this work. A liquid chromatography tandem mass spectrometry method using a 96-well format for sample preparation was developed and validated. PEth was extracted from DBSs by using isopropanol containing PEth-d5 as internal standard. The blood sampling used a commercial volumetric DBS device having a phosholipase D inhibitor incorporated to stop continuous PEth formation. The method quantified PEth in the range of 0.05-10 µmol/L, with a bias and imprecision of less than 15%. In a clinical study (n = 25) using fingerprick blood, the volumetric device offered more precise quantifications (CV 4.6%) compared with the Whatman 903 Protein Saver card device (CV 16.6%). In another clinical study (n = 48), the use of dried venous and capillary blood, and liquid venous blood was compared under real-life conditions with samples sent by postal service. The capillary and venous DBS samples gave identical results while the liquid blood gave slightly higher values. Calculation of elimination half-life (PEth 16:0/18:1) in 31 cases based on two consecutive samples with 2-9 days in between gave results (mean 6.2 days) that agree with literature but several cases with values over 10 days. In conclusion, this study demonstrates that volumetric DBS is a valid specimen for determination of PEth blood concentrations, offering several advantages.

4.
J Chromatogr A ; 1722: 464872, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38581975

RESUMO

LC-MS is an indispensable tool for small molecule analysis in many fields; however, many small molecules require chemical derivatization to improve retention on commonly used reversed-phase columns and increase ionization. Benzoyl chloride (BzCl) derivatization is commonly used for derivatization of primary and secondary amines and phenolic alcohols, though evidence exists that with proper reaction conditions (i.e., specific bases), other hydroxyl groups may be derivatized too. Previous studies have examined BzCl concentration, reaction times, and reaction temperatures for derivatization of amines and phenols for LC-MS analysis; however, use of different bases, base concentration, and extending to conditions to hydroxyl groups for LC-MS analysis has not been well-studied. To address this understudied area and identify reaction conditions for both amino and hydroxyl groups, we performed a systematic study of reaction conditions on multiple classes of potential targets. For selected derivatization methods, detection limits and performance in a variety of biological matrices were assessed. Results highlight the importance of tailoring derivatization methods for a given application as they varied by molecule and/or molecule class. Compared to the standard BzCl method commonly used, alternative methods were identified to better derivatize challenging analytes (glucosamine, choline, cortisol, uridine, cytidine) with detection limits reaching 1100, 9, 38, 170, and 67 nM compared to undetectable, 170, 86, 1000, and 86 nM respectively. Sub-nanomolar detection limits were achieved for norepinephrine with alternative derivatization approaches. Improved derivatization methods for several classes and molecules including nucleosides, steroids, and molecules containing hydroxyl groups were also identified.


Assuntos
Benzoatos , Espectrometria de Massas , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Limite de Detecção , Humanos , Aminas/análise , Aminas/química , Colina/análise , Colina/química , Hidrocortisona/análise , Hidrocortisona/química , 60705
5.
J Chromatogr A ; 1722: 464864, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38598890

RESUMO

In this study, a novel piperidinium-sulfonate based zwitterionic hydrophilic monolith was prepared through thermally initiated co-polymerization of a piperidinium-sulfonate monomer 3-(4-((methacryloyloxy)methyl)-1-methylpiperidin-1-ium-1-yl)propane-1-sulfonate (MAMMPS), and a hydrophilic crosslinker N,N'-methylenebisacrylamide (MBA) using n-propanol and H2O as porogenic system. Satisfactory mechanical and chemical stabilities, good repeatability and high column efficiency (120,000 N/m) were obtained on the optimal monolith. The resulting poly(MAMMPS-co-MBA) monolith showed a typical HILIC retention behavior over an ACN content range between 5 and 95 %. Furthermore, this column exhibited good separation performance for various polar compounds. Compared to quaternary ammonium-sulfonate based zwitterionic hydrophilic monolith, i.e. poly(N,N-dimethyl-N-methacryloxyethyl-N-(3-sulfopropyl)ammonium betaine-co-MBA), the poly(MAMMPS-co-MBA) monolith displayed stronger retention and better selectivity for the tested phenolic and amine compounds at different pH conditions. Finally, this column was applied for the separation of six sulfonamide antibiotics, and the analytical characteristics of the method were evaluated in terms of precision, repeatability, limits of detection (LOD) and quantitation (LOQ). Overall, this study not only developed a novel HILIC monolithic column, but also proved the potential of piperidinium-sulfonate based zwitterionic chemistry as stationary phase, which further increased the structure diversity of zwitterionic HILIC stationary phases.


Assuntos
Interações Hidrofóbicas e Hidrofílicas , Piperidinas , Piperidinas/isolamento & purificação , Piperidinas/química , Reprodutibilidade dos Testes , Ácidos Sulfônicos/química , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Acrilamidas/química , Polimerização , Acetonitrilas/química
6.
J Chromatogr A ; 1722: 464889, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38598894

RESUMO

In this paper, three imidazole- and C18- bifunctional silica stationary phases (Sil-Im-C18) were prepared by adjusting introduction interval of octadecyltrichlorosilane (ODS) and 3-imidazol-1-ylpropyl(trimethoxy)silane (TMPImS), which can be used for reversed-phase liquid chromatography (RPLC) and ion exchange chromatography (IEC) with adjustable performance. The successful preparation of Sil-Im-C18 were confirmed by the characterizations of elemental analysis, infrared spectroscopy (FTIR) and contact angle (CA). Chromatographic performance of Sil-Im-C18 were evaluated by the separation of Tanaka test mixture, alkylbenzenes, linear PAHs and a set of analytes with different properties (uracil, phenol, 1,2-dinitrobenzene and naphthalene), and compared with commonly used C18 column. It was found that the chromatographic performance of Sil-Im-C18 changed significantly with the difference in bonding amount of imidazole and C18. Sil-Im-C18 demonstrated the excellent separation performance towards polycyclic aromatic hydrocarbons (PAHs), phenylesters, phenylamines, phenols and inorganic anions, and notably, nucleobases and nucleosides can be separated using pure water as mobile phases. The van Deemter plot showed that the column efficiency of Sil-Im-C18-3 was 64,933 plate·m-1 for naphthalene, indicated that Sil-Im-C18 was reasonably chromatographic columns. The RSD values of retention time were 0.22 %-0.61 % for 10 needles alkylbenzenes injected continuously at 50 °C to investigate thermal stability and repeatability, all the fluctuations of k of naphthalene were less than 2.3 % for Sil-Im-C18-1 during flushing 24 h with the mobile phase at different pH values (pH = 3 and 8), the retention time of alkylbenzenes were almost same for Sil-Im-C18-1 at different time, the RSD values of retention time of alkylbenzenes were 0.45 %-2.28 % for two batches Sil-Im-C18-1, revealing the excellent repeatability, thermal stability, durability and reproducibility of Sil-Im-C18, and implying a commercial prospect.


Assuntos
Cromatografia de Fase Reversa , Imidazóis , Hidrocarbonetos Policíclicos Aromáticos , Dióxido de Silício , Imidazóis/química , Dióxido de Silício/química , Cromatografia de Fase Reversa/métodos , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/química , Silanos/química , Cromatografia por Troca Iônica/métodos
7.
J Chromatogr A ; 1722: 464867, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38598895

RESUMO

Hydrogels with a unique three-dimensional network structure have been widely used in a variety of fields. However, hydrogels are prone to swelling under water-rich conditions, which severely limits their application in liquid chromatography. Therefore, producing a hydrogel with reliable performance and good mechanical property is essential. Smart temperature-sensitive chromatographic packings have attracted extensive attentions in recent years. In this work, sodium 4-styrenesulfonate and 1-octadecene were introduced into the poly(N-isopropylacrylamide) hydrogel to improve mechanical property and separation performance. As a consequence, a smart temperature-sensitive terpolymeric hydrogel modified silica stationary phase (ION-hydrogel@SiO2) was synthesized for multimode liquid chromatographic separation. It was found that this new ION-hydrogel@SiO2 column exhibited excellent chromatographic separation ability for a wide range of analytes. To a certain extent, this new column has a higher chromatographic separation efficiency compared to the commercial C18 column and XAmide column. Moreover, the use of low proportion of organic phase in chromatographic separation is conducive to the realization of green chromatography. By investigating the chromatographic separation mechanism, it has been demonstrated that the hydrogen bonding interaction is primarily responsible for the temperature-sensitive behavior of the hydrogel. Finally, the ION-hydrogel@SiO2 column was used for the determination of pyridoxine in the commercially available tablet samples. In conclusion, this study presents a feasible idea for the development of novel copolymer hydrogels as liquid chromatographic stationary phases.


Assuntos
Resinas Acrílicas , Hidrogéis , Dióxido de Silício , Temperatura , Hidrogéis/química , Cromatografia Líquida/métodos , Dióxido de Silício/química , Resinas Acrílicas/química , Polímeros/química , Ligação de Hidrogênio
8.
J Chromatogr A ; 1722: 464874, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38598893

RESUMO

Hydroxypropyl methyl cellulose (HPMC) is a type of cellulose derivative with properties that render it useful in e.g. food, cosmetics, and pharmaceutical industry. The substitution degree and composition of the ß-glucose subunits of HPMC affect its physical and functional properties, but HPMC characterization is challenging due to its high structural heterogeneity, including many isomers. In this study, comprehensive two-dimensional liquid chromatography-mass spectrometry was used to examine substituted glucose monomers originating from complete acid hydrolysis of HPMC. Resolution between the different monomers was achieved using a C18 and cyano column in the first and second LC dimension, respectively. The data analysis process was structured to obtain fingerprints of the monomers of interest. The results revealed that isomers of the respective monomers could be selectively separated based on the position of substituents. The examination of two industrial HPMC products revealed differences in overall monomer composition. While both products contained monomers with a similar degree of substitution, they exhibited distinct regioselectivity.


Assuntos
Derivados da Hipromelose , Espectrometria de Massas , Hidrólise , Derivados da Hipromelose/química , Espectrometria de Massas/métodos , Cromatografia Líquida/métodos , Isomerismo , Glucose/química , Glucose/análise , 60705
9.
J Chromatogr A ; 1722: 464830, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38608366

RESUMO

Development of meaningful and reliable analytical assays in the (bio)pharmaceutical industry can often be challenging, involving tedious trial and error experimentation. In this work, an automated analytical workflow using an AI-based algorithm for streamlined method development and optimization is presented. Chromatographic methods are developed and optimized from start to finish by a feedback-controlled modeling approach using readily available LC instrumentation and software technologies, bypassing manual user intervention. With the use of such tools, the time requirement of the analyst is drastically minimized in the development of a method. Herein key insights on chromatography system control, automatic optimization of mobile phase conditions, and final separation landscape for challenging multicomponent mixtures are presented (e.g., small molecules drug, peptides, proteins, and vaccine products) showcased by a detailed comparison of a chiral method development process. The work presented here illustrates the power of modern chromatography instrumentation and AI-based software to accelerate the development and deployment of new separation assays across (bio)pharmaceutical modalities while yielding substantial cost-savings, method robustness, and fast analytical turnaround.


Assuntos
Software , Cromatografia Líquida/métodos , Algoritmos , Peptídeos/análise , Peptídeos/química , Proteínas/análise , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química , Inteligência Artificial , Vacinas/química , Vacinas/análise , Retroalimentação
10.
J Chromatogr A ; 1722: 464911, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38626541

RESUMO

In this study, we have synthesised a chiral l-hyp-Ni/Fe@SiO2 composite as a chiral stationary phase (CSP) for high-performance liquid chromatography (HPLC) for the first time. This was achieved by coating two-dimensional (2D) chiral metal-organic framework nanosheets (MONs) l-hyp-Ni/Fe onto the surface of activated SiO2 microspheres using the "wrapped in net" method. The separation efficiency of the l-hyp-Ni/Fe chromatographic column was systematically evaluated in normal-phase HPLC (NP-HPLC) and reversed-phase HPLC (RP-HPLC) configurations, employing various racemates as analytes. The findings revealed that 16 chiral compounds were separated using NP-HPLC, and five were separated using RP-HPLC, encompassing alcohols, amines, ketones, esters, alkanes, ethers, amino acids and sulfoxides. Notably, the resolution (Rs) of nine chiral compounds exceeded 1.5, indicating baseline separation. Furthermore, the resolution performance of the l-hyp-Ni/Fe@SiO2-packed column was compared with that of Chiralpak AD-H. It was observed that certain enantiomers, which either could not be resolved or were inadequately separated on the Chiralpak AD-H column, attained separation on the 2D chiral MONs column. These findings suggest a complementary relationship between the two columns in racemate separation, with their combined application facilitating the resolution of a broader spectrum of chiral compounds. In addition, baseline separation was achieved for five positional isomers on the l-hyp-Ni/Fe@SiO2-packed column. The effects of the analyte mass and column temperature on the resolution were also examined. Moreover, during HPLC analysis, the l-hyp-Ni/Fe columns demonstrated commendable repeatability, stability and reproducibility in enantiomer separation. This research not only advances the utilisation of 2D chiral MONs as CSPs but also expands their applications in the separation sciences.


Assuntos
Estruturas Metalorgânicas , Dióxido de Silício , Cromatografia Líquida de Alta Pressão/métodos , Dióxido de Silício/química , Estruturas Metalorgânicas/química , Estereoisomerismo , Nanoestruturas/química , Ferro/química , Níquel/química
11.
J Chromatogr A ; 1722: 464885, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38631223

RESUMO

Heightened interest in messenger RNA (mRNA) therapeutics has accelerated the need for analytical methodologies that facilitate the production of supplies for clinical trials. Forced degradation studies are routinely conducted to provide an understanding of potential weak spots in the molecule that are exploited by stresses encountered during bulk purification, production, shipment, and storage. Consequently, temperature fluctuations and excursions are often experienced during these unit operations and may accelerate mRNA degradation. Here, we present a concise panel of chromatography-based stability-indicating assays for evaluating thermally stressed in vitro transcribed (IVT) mRNA as part of a forced degradation study. We found that addition of EDTA to the mRNAs prior to heat exposure reduced the extent of degradation, suggesting that transcripts may be fragmenting via a divalent metal-ion mediated pathway. Trace divalent metal contamination that can accelerate RNA instability is likely carried over from upstream steps. We demonstrate the application of these methods to evaluate the critical quality attributes (CQAs) of mRNAs as well as to detect intrinsic process- and product-related impurities.


Assuntos
Estabilidade de RNA , RNA Mensageiro , Ácido Edético/química , Transcrição Gênica , Temperatura Alta
12.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 55(2): 425-432, 2024 Mar 20.
Artigo em Chinês | MEDLINE | ID: mdl-38645843

RESUMO

Objective: To establish quality standards for Liuwei Nengxiao pills, to optimize the quality control method, and to provide references for the quality control of Liuwei Nengxiao pills. Methods: Chebula, dried ginger, and Tibetan liqueur root in Liuwei Nengxiao pills of different batch numbers were analyzed by thin layer chromatography (TLC). Then, the content of chrysophanol in the preparation was determined by high performance liquid chromatography (HPLC). Furthermore, a series of methodological validation, including the investigation of the linear relationship, precision, stability, and reproducibility and sample recovery test, were performed to verify the reliability of the results. Results: The TLC identification method was easy to perform and demonstrated high specificity, clear spots, and good separation effect. In addition, the negative controls showed no interference. The HPLC method showed high accuracy. The results of methodological validation showed that the peak area of chrysophanol had a good linear relationship (r2=1.0) in the range of 0.06-0.80 µg, presenting good precision (with the relative standard deviation being lower than 2.0%), good stability and reproducibility (with the relative standard deviation being lower than 1.0%), and an average recovery rate of 100.8%. Conclusion: TLC and HPLC are easy to perform, showing high accuracy and reproducibility. The quality standards established are scientific, reasonable, stable, and feasible, providing references for the quality control of Liuwei Nengxiao pills.


Assuntos
Antraquinonas , Medicamentos de Ervas Chinesas , Medicina Tradicional Tibetana , Controle de Qualidade , Medicamentos de Ervas Chinesas/normas , Medicamentos de Ervas Chinesas/química , Cromatografia Líquida de Alta Pressão/métodos , Medicina Tradicional Tibetana/normas , Cromatografia em Camada Delgada/métodos , Reprodutibilidade dos Testes
13.
Pract Lab Med ; 40: e00393, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38645932

RESUMO

Objectives: Salivary cortisol reflects the biologically active form of serum cortisol, offering a noninvasive evaluation method for the diurnal rhythm of the hypothalamic-pituitary-adrenal (HPA) axis. While liquid chromatography-tandem mass spectrometry (LC-MS/MS) is known for its specificity, immunoassays (IA) are commonly used because of their simplicity. This study aimed to assess the performance of salivary cortisol measurement using both IA and LC-MS/MS in comparison to serum-free cortisol measurement. Methods: Assay results for 188 saliva and 94 serum samples from 47 participants were analyzed. Salivary samples collected at different time points were analyzed using IA and LC-MS/MS. Serum samples were analyzed for cortisol, cortisol-binding globulin, and free cortisol. The statistical analyses included correlations and method comparisons. Results: The diurnal salivary cortisol profiles exhibited a comparable circadian rhythm pattern; however, the concentrations measured using IA were consistently higher than those measured using LC-MS/MS. The correlation analysis revealed robust associations among salivary cortisol (IA), salivary cortisol (LC-MS/MS), and serum-free cortisol levels (LC-MS/MS). However, the method comparison revealed a systematic bias between IA and LC-MS/MS in salivary cortisol measurement. Conclusions: This study contributes to the ongoing debate on assay techniques by affirming the suitability of IA and LC-MS/MS for salivary cortisol measurement to assess dynamic changes in HPA axis activity. The identified systematic bias emphasizes the importance of selecting methods based on specific research or clinical requirements.

14.
Toxins (Basel) ; 16(4)2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38668595

RESUMO

Ciguatera poisoning (CP) is the most common type of marine biotoxin food poisoning worldwide, and it is caused by ciguatoxins (CTXs), thermostable polyether toxins produced by dinoflagellate Gambierdiscus and Fukuyoa spp. It is typically caused by the consumption of large fish high on the food chain that have accumulated CTXs in their flesh. CTXs in trace amounts are found in natural samples, and they mainly induce neurotoxic effects in consumers at concentrations as low as 0.2 µg/kg. The U.S. Food and Drug Administration has established CTX maximum permitted levels of 0.01 µg/kg for CTX1B and 0.1 µg/kg for C-CTX1 based on toxicological data. More than 20 variants of the CTX1B and CTX3C series have been identified, and the simultaneous detection of trace amounts of CTX analogs has recently been required. Previously published works using LC-MS/MS achieved the safety levels by monitoring the sodium adduct ions of CTXs ([M+Na]+ > [M+Na]+). In this study, we optimized a highly sensitive method for the detection of CTXs using the sodium or lithium adducts, [M+Na]+ or [M+Li]+, by adding alkali metals such as Na+ or Li+ to the mobile phase. This work demonstrates that CTXs can be successfully detected at the low concentrations recommended by the FDA with good chromatographic separation using LC-MS/MS. It also reports on the method's new analytical conditions and accuracy using [M+Li]+.


Assuntos
Ciguatoxinas , Espectrometria de Massas em Tandem , Ciguatoxinas/análise , Cromatografia Líquida , Lítio/análise , Intoxicação por Ciguatera , Contaminação de Alimentos/análise , Limite de Detecção , Animais
15.
J Chromatogr A ; 1722: 464843, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38574599

RESUMO

Reversed-phase high performance liquid chromatography (RP-HPLC) is the most widely used chromatographic method. In addition to hydrophobic interactions, additional interactions such as electrostatic interactions may participate in the retention behaviour of an analyte. This makes it possible to use RP-HPLC for many types of analyte. We describe a simple method for separating inorganic anions on a C18 column, in which retention of inorganic anions is almost entirely due to electrostatic interactions. This leads to rapid separations as well as higher theoretical plate numbers. We used 2 mM phosphoric acid containing a low concentration of disodium molybdate as the mobile phase, which allows UV detection of non-UV-absorbing anions. With this method, we determined eight inorganic anions including several non-UV-absorbing anions photometrically at 220 nm. The detection limits of the examined eight inorganic anions calculated at a signal-to-noise ratio of 3 were between 0.3 and 10 µM. The detector response was linear over three orders of magnitude of inorganic anion concentration. The proposed RP-HPLC/UV method was successfully applied to determine inorganic anions in some water samples.


Assuntos
Ânions , Cromatografia de Fase Reversa , Molibdênio , Ácidos Fosfóricos , Ânions/química , Molibdênio/química , Ácidos Fosfóricos/química , Cromatografia de Fase Reversa/métodos , Cromatografia Líquida de Alta Pressão/métodos , Limite de Detecção
16.
Phytochem Anal ; 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38639073

RESUMO

INTRODUCTION: The active constituents in Aurantii Fructus sourced from different regions within Hunan Province exhibit variations, with certain samples demonstrating substandard quality. OBJECTIVES: The aim of this study is to conduct a comparative analysis of the chemical composition and quality of Aurantii Fructus from various sources, establish a robust methodology for quality evaluation, and determine the optimal harvesting period. MATERIALS AND METHODS: The components of Aurantii Fructus were qualitatively analyzed using a non-targeted metabolomics approach. Multivariate statistical analyses were conducted to identify potential markers, enabling qualitative and quantitative evaluation of the quality and optimal harvest period of Aurantii Fructus. RESULTS: Overall, 155 compounds were identified in Aurantii Fructus, with Huangpi exhibiting the highest number of components. Eleven potential markers were selected to assess the quality of Aurantii Fructus. The average content of Huangpi was the highest, indicating a high level of similarity. The samples' overall scores were ordered as follows: Huangpi > Xiangcheng > Choucheng > Daidai. Anren and Changde's Huangpi exhibited high contents, being rich in chemical components, resulting in favorable scores. Similarly, Changde's Xiangcheng displayed significant medicinal value. As the harvest time was delayed, there was an increase in fruit size, accompanied by thinner peels and a continuous decrease in the contents of potential markers. The best harvest period of Aurantii Fructus was within 1 week before and after the Lesser Heat. CONCLUSION: The present study establishes a precise and efficient method for evaluating the quality of Aurantii Fructus, thereby providing more comprehensive insights into its composition. This research lays the foundation for subsequent development and utilization of Aurantii Fructus.

17.
Am J Clin Pathol ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38639326

RESUMO

OBJECTIVES: Voxelotor can increase hemoglobin levels in patients living with sickle cell disease (SCD). A clinician who is monitoring voxelotor response may want to know whole-blood voxelotor concentration, but this cannot be measured in most clinical settings. However, voxelotor has been demonstrated to cause "peak splitting" in common methods of hemoglobin measurement such as capillary zone electrophoresis (CZE) and high-performance liquid chromatography (HPLC). We hypothesized that we could use the size of the peak split to estimate the whole-blood concentration. METHODS: Blood from people with SCD was dosed with known concentrations of voxelotor, and multiparameter regression was used to derive the relationship of voxelotor concentration to the degree of peak splitting observed. To validate these equations, 21 patients started on voxelotor at 1500 mg/d had blood samples drawn at days 0, 14, 30, and 60. Samples were sent out for gold standard voxelotor concentration testing. The derived equations were then used to calculate voxelotor concentration. RESULTS: Calculated concentrations correlated strongly with measured concentrations for both CZE (R2 = 0.83, P < .001) and HPLC (R2 = 0.76, P < .001). Voxelotor concentration also had a significant effect on increases in hemoglobin (R2 = 0.40, P < .001). CONCLUSIONS: Thus, peak splitting CZE and HPLC can be used to estimate voxelotor concentration.

18.
Talanta ; 275: 126116, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38640518

RESUMO

Fragmentation characteristics are crucial for nontargeted screening to discover and identify unknown exogenous chemical residues in animal-derived foods. In this study, first, fragmentation characteristics of 51 classes of exogenous chemical residues were summarized based on experimental mass spectra of standards in reversed-phase and hydrophilic interaction liquid chromatography-high-resolution mass spectrometry (MS) and mass spectra from the MassBank of North America (MoNA) library. According to the proportion of fragmentation characteristics to the total number of chemical residues in each class, four screening levels were defined to classify 51 classes of chemical residues. Then, a nontargeted screening method was developed based on the fragmentation characteristics. The evaluation results of 82 standards indicated that more than 90 % of the chemical residues with MS/MS spectra can be identified at concentrations of 100 and 500 µg/kg, and about 80 % can be identified at 10 µg/kg. Finally, the nontargeted screening method was applied to 16 meat samples and 21 egg samples as examples. As a result, eight chemical residues and transformation products (TPs) of 5 classes in the exemplary samples were found and identified, in which 3 TPs of azithromycin were identified by fragmentation characteristics-assisted structure interpretation. The results demonstrated the practicability of the nontargeted screening method for routine risk screening of food safety.

19.
Water Res ; 256: 121570, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38640564

RESUMO

Per- and polyfluoroalkyl substances (PFAS) are environmental contaminants of concern due to their long persistence in the environment, toxicity, and widespread presence in humans and wildlife. Knowledge regarding the extent of PFAS contamination in the environment is limited due to the need for analytical methods that can reliably quantify all PFAS, since traditional target methods using liquid chromatography (LC)-mass spectrometry (MS) fail to capture many. For a more comprehensive analysis, a total organic fluorine (TOF) method can be used as a screening tool. We combined TOF analysis with target LC-MS/MS analysis to create a statewide PFAS hotspot map for surface waters throughout South Carolina. Thirty-eight of 40 locations sampled contained detectable concentrations of organic fluorine (above 100 ng/L). Of the 33 target PFAS analyzed using LC-MS/MS, the most prevalent were perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluoroheptanoic acid (PFHpA), and perfluorohexanesulfonate (PFHxS). On average, LC-MS/MS only accounted for 2 % of the TOF measured. Locations with high TOF did not necessarily correlate to high total quantified PFAS concentrations and vice-versa, demonstrating the limitations of target PFAS analysis and indicating that LC-MS may miss highly contaminated sites. Results suggest that future surveys should utilize TOF to more comprehensively capture PFAS in water bodies.

20.
Artigo em Inglês | MEDLINE | ID: mdl-38640794

RESUMO

Chromatography is a robust and reliable separation method that can use various stationary phases to separate complex mixtures commonly seen in metabolomics. This review examines the types of chromatography and stationary phases that have been used in targeted or untargeted metabolomics with methods such as mass spectrometry (MS) and nuclear magnetic resonance (NMR) spectroscopy. General considerations for sample pretreatment and separations in metabolomics are considered, along with the various supports and separation formats for chromatography that have been used in such work. The types of liquid chromatography (LC) that have been most extensively used in metabolomics will be examined, such as reversed-phase liquid chromatography and hydrophilic liquid interaction chromatography. In addition, other forms of LC that have been used in more limited applications for metabolomics (e.g., ion-exchange, size-exclusion, and affinity methods) will be discussed to illustrate how these techniques may be utilized for new and future research in this field. Multidimensional LC methods are also discussed, as well as the use of gas chromatography and supercritical fluid chromatography in metabolomics. In addition, the roles of chromatography in NMR- vs. MS-based metabolomics are considered. Applications are given within the field of metabolomics for each type of chromatography, along with potential advantages or limitations of these separation methods.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...